Leading the world in
energy absorption

| Type 110/500

Type 110/500

Type 110/500 (Type 110)

Product Description

The type 110 buffer is a highly modular design allowing the same components to be used in a variety of applications.

The type 110 buffer comes with a standard chrome finish for non corrosive environments such as factory buildings and optional marine plating for more corrosive environments such as docksides and ports.

The type 110 is specified for the following usage:

  • 3,500 cycles at 10% of rated load (corresponds with a daily impact of the unit at 10 years life)

  • 500 cycles at 50% of rated load (corresponds with a weekly impact at 10 years life)

  • 12 cycles at full load, which is the equivalent of: • One installation test

  • One test every year for 10 years

  • One emergency operation

  • Operating temperature range of -30°C to +100°C.

Note:
* Where bellows are fitted L1 and L2 are +10mm

Back Mount – 200mm, 300mm, 400mm STROKE ONLY

Double Foot Mount –  Foot mounted units should employ a backstop as buffer loads should not be exerted through foot bolts alone

  Metric Imperial
Rated speed
Maximum speed (115%)
Stroke 'S' (min.)
Impact mass range kg lbs
Height 'H' max. (extended)
Height 'C' min. (compressed)
Height 'F' to reservoir top
Weight no oil (dry)
Oil volume
Reduced stroke: Rated speed with terminal speed limiting device, based on EN81.1 rule 10.4.3.2 and ASME A17.1 rule 2.22.4.1.2
Reduced stroke ASME A17.1
Reduced stroke EN81.1